[edit] Logic control
Pure logic control systems were historically implemented by electricians with networks of relays, and designed with a notation called ladder logic. Today, most such systems are constructed with programmable logic devices.
Logic controllers may respond to switches, light sensors, pressure switches etc and cause the machinery to perform some operation. Logic systems are used to sequence mechanical operations in many applications. Examples include elevators, washing machines and other systems with interrelated stop-go operations.
Logic systems are quite easy to design, and can handle very complex operations. Some aspects of logic system design make use of Boolean logic.

[edit] On-off control
For example, a thermostat is a simple negative-feedback control: when the temperature (the "measured variable" or MV) goes below a set point (SP), the heater is switched on. Another example could be a pressure-switch on an air compressor: when the pressure (MV) drops below the threshold (SP), the pump is powered. Refrigerators and vacuum pumps contain similar mechanisms operating in reverse, but still providing negative feedback to correct errors.
Simple on-off feedback control systems like these are cheap and effective. In some cases, like the simple compressor example, they may represent a good design choice.
In most applications of on-off feedback control, some consideration needs to be given to other costs, such as wear and tear of control valves and maybe other start-up costs when power is reapplied each time the MV drops. Therefore, practical on-off control systems are designed to include hysteresis, usually in the form of a deadband, a region around the setpoint value in which no control action occurs. The width of deadband may be adjustable or programmable.

[edit] Linear control
Linear control systems use linear negative feedback to produce a control signal mathematically based on other variables, with a view to maintaining the controlled process within an acceptable operating range.
The output from a linear control system into the controlled process may be in the form of a directly variable signal, such as a valve that may be 0 or 100% open or anywhere in between. Sometimes this is not feasible and so, after calculating the current required corrective signal, a linear control system may repeatedly switch an actuator, such as a pump, motor or heater, fully on and then fully off again, regulating the duty cycle using pulse-width modulation.

[edit] Proportional control
When controlling the temperature of an industrial furnace, it is usually better to control the opening of the fuel valve in proportion to the current needs of the furnace. This helps avoid thermal shocks and applies heat more effectively.
Proportional negative-feedback systems are based on the difference between the required set point (SP) and measured value (MV) of the controlled variable. This difference is called the error. Power is applied in direct proportion to the current measured error, in the correct sense so as to tend to reduce the error (and so avoid positive feedback). The amount of corrective action that is applied for a given error is set by the gain or sensitivity of the control system.
At low gains, only a small corrective action is applied when errors are detected: the system may be safe and stable, but may be sluggish in response to changing conditions; errors will remain uncorrected for relatively long periods of time: it is over-damped. If the proportional gain is increased, such systems become more responsive and errors are dealt with more quickly. There is an optimal value for the gain setting when the overall system is said to be critically damped. Increases in loop gain beyond this point will lead to oscillations in the MV; such a system is under-damped.

[edit] Under-damped furnace example
In the furnace example, suppose the temperature is increasing towards a set point at which, say, 50% of the available power will be required for steady-state. At low temperatures, 100% of available power is applied. When the MV is within, say 10° of the SP the heat input begins to be reduced by the proportional controller. (Note that this implies a 20° "proportional band" (PB) from full to no power input, evenly spread around the setpoint value). At the setpoint the controller will be applying 50% power as required, but stray stored heat within the heater sub-system and in the walls of the furnace will keep the measured temperature rising beyond what is required. At 10° above SP, we reach the top of the proportional band (PB) and no power is applied, but the temperature may continue to rise even further before beginning to fall back. Eventually as the MV falls back into the PB, heat is applied again, but now the heater and the furnace walls are too cool and the temperature falls too low before its fall is arrested, so that the oscillations continue.

[edit] Over-damped furnace example
The temperature oscillations that an under-damped furnace control system produces are unacceptable for many reasons, including the waste of fuel and time (each oscillation cycle may take many minutes), as well as the likelihood of seriously overheating both the furnace and its contents.
Suppose that the gain of the control system is reduced drastically and it is restarted. As the temperature approaches, say 30° below SP (60° proportional band or PB now), the heat input begins to be reduced, the rate of heating of the furnace has time to slow and, as the heat is still further reduced, it eventually is brought up to set point, just as 50% power input is reached and the furnace is operating as required. There was some wasted time while the furnace crept to its final temperature using only 52% then 51% of available power, but at least no harm was done. By carefully increasing the gain (i.e. reducing the width of the PB) this over-damped and sluggish behavior can be improved until the system is critically damped for this SP temperature. Doing this is known as 'tuning' the control system. A well-tuned proportional furnace temperature control system will usually be more effective than on-off control, but will still respond slower than the furnace could under skillful manual control.

[edit] PID control
Main article: PID controller
Apart from sluggish performance to avoid oscillations, another problem with proportional-only control is that power application is always in direct proportion to the error. In the example above we assumed that the set temperature could be maintained with 50% power. What happens if the furnace is required in a different application where a higher set temperature will require 80% power to maintain it? If the gain was finally set to a 50° PB, then 80% power will not be applied unless the furnace is 15° below setpoint, so for this other application the operators will have to remember always to set the setpoint temperature 15° higher than actually needed. This 15° figure is not completely constant either: it will depend on the surrounding ambient temperature, as well as other factors that affect heat loss from or absorption within the furnace.
To resolve these two problems, many feedback control schemes include mathematical extensions to improve performance. The most common extensions lead to proportional-integral-derivative control, or PID control (pronounced pee-eye-dee).

[edit] Derivative action
The derivative part is concerned with the rate-of-change of the error with time: If the measured variable approaches the setpoint rapidly, then the actuator is backed off early to allow it to coast to the required level; conversely if the measured value begins to move rapidly away from the setpoint, extra effort is applied — in proportion to that rapidity — to try to maintain it.
Derivative action makes a control system behave much more intelligently. On systems like the temperature of a furnace, or perhaps the motion-control of a heavy item like a gun or camera on a moving vehicle, the derivative action of a well-tuned PID controller can allow it to reach and maintain a setpoint better than most skilled human operators could.
If derivative action is over-applied, it can lead to oscillations too. An example would be a temperature that increased rapidly towards SP, then halted early and seemed to "shy away" from the setpoint before rising towards it again.

[edit] Integral action
The integral term magnifies the effect of long-term steady-state errors, applying ever-increasing effort until they reduce to zero. In the example of the furnace above working at various temperatures, if the heat being applied does not bring the furnace up to setpoint, for whatever reason, integral action increasingly moves the proportional band relative to the setpoint until the time-integral of the MV error is reduced to zero and the setpoint is achieved.

[edit] Other techniques
Another common technique is to filter the MV or error signal. Such a filter can reduce the response of the system to undesirable frequencies, to help eliminate instability or oscillations. Some feedback systems will oscillate at just one frequency. By filtering out that frequency, one can use very "stiff" feedback and the system can be very responsive without shaking itself apart.
The most complex linear control systems developed to date are in oil refineries[citation needed] (model predictive control). The chemical reaction paths and control systems are normally designed together using specialized computer-aided-design software.
Feedback systems can be combined in many ways. One example is cascade control in which one control loop applies control algorithms to a measured variable against a setpoint, but then actually outputs a setpoint to another controller, rather than affecting power input directly.
Usually if a system has several measurements to be controlled, feedback systems will be present for each of them.

[edit] Fuzzy logic
Fuzzy logic is an attempt to get the easy design of logic controllers and yet control continuously-varying systems. Basically, a measurement in a fuzzy logic system can be partly true, that is if yes is 1 and no is 0, a fuzzy measurement can be between 0 and 1.
The rules of the system are written in natural language and translated into fuzzy logic. For example, the design for a furnace would start with: "If the temperature is too high, reduce the fuel to the furnace. If the temperature is too low, increase the fuel to the furnace."
Measurements from the real world (such as the temperature of a furnace) are converted to values between 0 and 1 by seeing where they fall on a triangle. Usually the tip of the triangle is the maximum possible value which translates to "1."
Fuzzy logic then modifies Boolean logic to be arithmetical. Usually the "not" operation is "output = 1 - input," the "and" operation is "output = input.1 multiplied by input.2," and "or" is "output = 1 - ((1 - input.1) multiplied by (1 - input.2))."
The last step is to "defuzzify" an output. Basically, the fuzzy calculations make a value between zero and one. That number is used to select a value on a line whose slope and height converts the fuzzy value to a real-world output number. The number then controls real machinery.
If the triangles are defined correctly and rules are right the result can be a good control system.
When a robust fuzzy design is reduced into a single, quick calculation, it begins to resemble a conventional feedback loop solution. For this reason, many control engineers think one should not bother with it. However, the fuzzy logic paradigm may provide scalability for large control systems where conventional methods become unwieldy or costly to derive.
Fuzzy electronics is an electronic technology that uses fuzzy logic instead of the two-value logic more commonly used in digital electronics.

Friday, September 12, 2008

history

A BRIEF HISTORY OF AUTOMATION: The Past, Present and Future of the Industry
By Stefani MingoMay 15, 2000
In 1981, IBM introduced its personal computer (PC) for use in the home, office and schools. Prior to that time, there had been several MS-DOS compatible personal computers that ran DOS programs. As computers became more widespread in the workplace (ie. an independent agent's office), new ways to unleash their potential developed. As smaller computers became more powerful, they could be linked together, or networked, to share memory space, software and information, and communicate with each other.
So where does the insurance industry enter the "automation" picture?
Independent agents have come a long way in using technology over the past 20 years. From the early 1980s through the mid-1990s, independent agents for the most part used PC-based automation systems to boost efficiency and cut costs.
Since 1970, ACORD, a not-for-profit standards-setting association for the insurance industry, has been involved in automation. The association is comprised of carriers, agents, vendors, solution providers, associations and other interested parties. "We aren't the ones who 'built' the automation system," said Carolyn "Cal" Durland, managing director of Standards for ACORD. "What we did and still do is provide standards-Forms and Electronic Data Interchange (EDI) upon which the vendors or solution providers base their automation systems." She explained that to find out how the industry became automated, one must look to the vendors and solution providers.
In 1972, the first ACORD form, a property loss notice, went into use. Today, ACORD's standards include Forms, AL3 (Automation Level 3), XML, OLife and ObjX. The Forms are point of sale, data collection vehicles, AL3 is ACORD's EDI standard (or machine-to-machine, business-to-business, data transmission formats or components), OLife is a data integration standard and ObjX is "much more than EDI."
In the 1980s-when the number of PCs in use increased dramatically-ACORD members asked for standardized electronic transmissions between the agents' computers and the carriers' computers.
"The industry has come to ACORD to consolidate efforts to eliminate duplication of work," Durland said. "For example, without one approved, countrywide ACORD application, all of the 2,400-plus insurance carriers would have to have their own form. And the vendors or solution providers who automate those forms would have to customize each form."
Now that ACORD and the industry are working hand-in-hand, there is one form accepted and used by many of those carriers. In addition, the vendors or solution providers have the option to become licensed by ACORD to redistribute the Forms. "ACORD provides them with tools...to print the ACORD Forms," Durland said. "ACORD's Forms efforts have stripped the costs out of this distribution channel."
According to Durland, in the same manner that the industry came together with ACORD to do Forms, they have also worked to develop EDI Standards. "Through our subcommittee process and strict compliance to anti-trust guidelines, we bring together carriers, agents, vendors, solution providers and other interested parties to discuss what is needed to transmit the data collected," she said.
Change is goodThe industry on the whole, according to Durland, is slow to make changes, "although there are some carriers that have the resources to be on the leading edge of technology."
The beginning was a bit archaic. "Carriers realized the benefits of automation and developed proprietary systems that they placed in the agents' offices," Durland said. "This resulted in the agents having to physically go from one terminal to another to interface with the carriers automating their process."
With the inception of the agency management vendors and ACORD's standards implemented in those systems, the agents were conceptually able to eliminate those proprietary terminals and work through one system. "This concept called SEMCI, Single Entry Multiple Company Interface, allowed the agents to keep the data in one place and transmit it electronically to any of the carriers it was licensed to represent," Durland explained.
One step forward, two steps backTen years ago, when Durland joined ACORD, there were many agency management systems attempting to enable SEMCI. "Today, due to acquisitions and mergers, there are three primary vendors and a few smaller ones," she said. "SEMCI is still the goal for the agents and the carriers. However, with the inception of Web enabled processes, the carriers-in an effort to streamline their costs-reverted back to proprietary applications.
"Those leading edge carriers put up Web sites that required the agent to go to the site and enter the information. So instead of going to a separate terminal in their office, they now had to connect to a Web site and rekey the data that was already in their databases."
This resulted in the acceptance of the new standard XML. "XML is a standard that enables connectivity between Web applications and agency management systems, in addition to business-to-business, business-to-customer, etc.," Durland said.
The goal to secure SEMCI, according to Durland, can still happen with the implementation of XML. "Plus it broadens the trading partner base to be more than the agent to insurance carrier," she said.
A push for implementationIn the 1990s, implementation guides were written and a certification process was developed. Today, there are more than 12,000 upload and 40,000 download implementations using AL3 standards. AL3 continues to evolve and there are new implementations every day, including using AL3 standards over the Internet.
Ever since the dawn of the industry's automation, forms standardization continued and still continues to be an important focus for ACORD as the standards-setting association works with many different trading partners within the industry.
Today there are roughly 400 ACORD forms. And although it's important to note how many forms there are, what is even more important to note is the fact that these ACORD forms have eliminated or prevented 80,000 proprietary forms-saving the industry millions of dollars.
Communicating on a global basisAccording to Durland, ACORD has staff dedicated to building relationships with other standards-setting organizations. The fact is, the industry handles business on a global basis, so it just makes sense that the goal is to be able to communicate on a global basis.
As an example, Durland pointed out that carriers write coverage for properties owned by people all over the world. In turn, these carriers work with other carriers or reinsurers to share the exposure.
When asked why it is so important for the industry to be automated, Durland said, "Automation strips costs out of workflows." Simply put, to only have to go to one place for information and to be able to service customers quickly and efficiently is key.
"For example, the agent and carrier agree to indemnify the customer if they have a loss which is covered under their policy. The customer pays a fee based on that promise. When the loss occurs, they want someone to handle it promptly...to be given information on the progression of the resolution...and be paid or have the item replaced ASAP," Durland said.
Automation makes it possible.
"With the technology and automation available to us today, the opportunities to share information are unlimited," Durland said. "The industry realizes that and is working together to figure out how to communicate electronically with each other."

automation

Automation, the rule that overruled the industry. there is no industry without automation. the automation people is going to be the backbone of the industries....................